Page 20
RELAY FUNCTIONS
1 324 756 8
4. Dip-Switch Settings
a. Interlocked Functions
Interlocked means the two adjacent push buttons can not be activated simultaneously at the
same time as it will cancel each other out. Interlocked settings are usually applied to crane’s
forward and reverse motions. Each dip-switch on the decoder module corresponds to one (1)
motion or two (2) adjacent push buttons (refer to Fig. 14 & 15 below). Only the first 7
dip-switch positions are used (counting from left to right), the 8
th
dip-switch position (far right)
is not used.
(Fig. 14)
(Fig. 15)
▇ Manufacture preset
Dip
Settings
Function Descriptions
# of Relays
Used
0000000 Normal (single speed only, F2 & R2 relays not used)
2
0000001 Closed/Closed Relay Action at 2
nd
Speed (separate 2
nd
speed relay)
4
0000010 Closed/Closed Relay Action at 2
nd
Speed (shared 2
nd
speed relay)
3
0000011 Opened/Closed Relay Action at 2
nd
Speed (separate 2
nd
speed relay)
4
0000110 On (right button) & Off (left button)
2
0001000
On & Off (affected by the E-stop command. When E-stop
command is initiated, the Off relay is activated)
2
0000111 Safety Magnet On & Off
2
0100001 Closed/Closed + Brake
4
0100010 Closed/Closed Relay Action + Brake
3
0100011 Opened/Closed Relay Action + Brake
4