Magnetek Flex 12EX System Manuál s instrukcemi Strana 45

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 48
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 44
Flex 12EX System Instruction Manual
December 2013
Page 45 of 48
7.2 STATUS LIGHT INDICATORS & WARNINGS
7.2.1Transmitter STATUS Light Indication
Type Display Type Indication
1
Constant red
Voltage goes below 1.9V at initial power on -
transmitter power shuts off.
Voltage goes below 1.8V during operation -
transmitter power shuts off. Turn the power off
to disengage the receiver main.
2
1 red blink followed by a 2-
second pause
Voltage goes below 1.85V during operation -
change batteries immediately.
3
2 red blinks followed by a 2-
second pause
The pushbutton is defective after turning on the
transmitter power.
4
No light displayed
When a defective push button condition occurs
(2 red blinks, type 3 above), find out which push
button is defective by pressing all the push
buttons on the transmitter one at a time. If the
push button is in good working order, the LED
will not light up when pressed. If the push
button is defective the LED will continue to
display 2 red blinks when pressed.
5
3 red blinks followed by a 2-
second pause
EEPROM error.
6
4 red blinks followed by a 2-
second pause
Transmitting error, system can not lock on
to the designated channel.
7
Constant green for up to 2
seconds
Transmitter power on with no faults detected
(prior to initiating the START function).
8
Blinking green Pushbutton pressed, signal transmitted.
9
Slow red blinks
Stop command initiated with receiver
MAIN deactivated.
10
1 orange blink every 4 seconds Transmitter on standby.
Zobrazit stránku 44
1 2 ... 40 41 42 43 44 45 46 47 48

Komentáře k této Příručce

Žádné komentáře